Recupera Dry-300 is an integrated Controlled Mechanical Ventilation (CMV) solution with dehumidification and air treatment for rooms in the home. By combining it with a radiant system and single air distribution system, the air can be treated throughout the different seasons, thus satisfying a complete range of comfort needs.
With Recupera Dry-300, the following air treatments are possible.
In Summer:
In Winter:
The air flow rates of Recupera Dry-300 can be set from the control panel; the electric fan speed is automatically adjusted to ensure the pre-set air flow rate in the distribution ducts and avoid any pressure drops.
The air introduced in the room can be composed of two air flows: the renewed flow with heat recovery, and the recirculated air flow.
The heating/cooling/dehumidification treatments always provide for a recirculated ambient air flow.
The renewed and recirculated flows can be combined or otherwise, depending on the flow rates and type of treatment to be carried out.
The machine is made of a galvanised sheet metal structure with special thermal and acoustic insulation, which contains: a direct expansion cooling circuit to dehumidify the air, a supplementary finned exchanger to be connected to the heating system for summer/winter integration, a high-efficiency air/air heat recuperator, motorised dampers to regulate the respective air flow rates, inspectionable G4 filters positioned in the respective unit air inlet ducts, two “brushless” variable-flow electric fans, one condensate drain pan, an electrical cabinet and remote control panel to be installed on a guide in a wall-mounted electrical cabinet.
The machine is equipped with a remote control panel to be mounted on a DIN rail in a wall-mounted electrical cabinet. The control panel is equipped with no. 3 terminal blocks for connection of:
Functions that can be activated via the digital inputs:
Settings available from keypad:
It is also possible to read the values of the temperature sensors used by the machine, particularly useful during commissioning or operational testing.
Recupera Dry-500 is an integrated Controlled Mechanical Ventilation (CMV) solution with dehumidification and air treatment for rooms in the home. By combining it with a radiant system and single air distribution system, the air can be treated throughout the different seasons, thus satisfying a complete range of comfort needs.
With Recupera Dry-500, the following air treatments are possible.
In Summer:
In Winter:
The air flow rates of Recupera Dry-500 can be set from the control panel; the electric fan speed is automatically adjusted to ensure the pre-set air flow rate in the distribution ducts and avoid any pressure drops.
The air introduced in the room can be composed of two air flows: the renewed flow with heat recovery, and the recirculated air flow.
The heating/cooling/dehumidification treatments always provide for a recirculated ambient air flow.
The renewed and recirculated flows can be combined or otherwise, depending on the flow rates and type of treatment to be carried out.
The machine is made of a galvanised sheet metal structure with special thermal and acoustic insulation, which contains: a direct expansion cooling circuit to dehumidify the air, a supplementary finned exchanger to be connected to the heating system for summer/winter integration, a high-efficiency air/air heat recuperator, motorised dampers to regulate the respective air flow rates, inspectionable G4 filters positioned in the respective unit air inlet ducts, two “brushless” variable-flow electric fans, one condensate drain pan, an electrical cabinet and remote control panel to be installed on a guide in a wall-mounted electrical cabinet.
The machine is equipped with a remote control panel to be mounted on a DIN rail in a wall-mounted electrical cabinet. The control panel is equipped with no. 3 terminal blocks for connection of:
Functions that can be activated via the digital inputs:
Settings available from keypad:
It is also possible to read the values of the temperature sensors used by the machine, particularly useful during commissioning or operational testing.
Recupera DRY-300
Technical characteristics:
Renewal only operation:
Operation in renewal + recirculation (with dehumification):
(*) Internal ambient air intake: 26 ° C; 65% RH; External ambient air intake 35 ° C; 50% RH; Inlet water temperature 15 ° C.
Recupera DRY-500
Technical characteristics:
Renewal only operation:
Operation in renewal + recirculation (with dehumification):
(*) Internal ambient air intake: 26 ° C; 65% RH; External ambient air intake 35 ° C; 50% RH; Inlet water temperature 15 ° C.